Craton Shield
vs-opcua-monitor
vs-opcua-monitor
OPC UA security monitor for Craton Shield (IEC 62443).
Overview
Monitors OPC UA traffic for security violations in industrial control systems. Designed for SCADA gateways and industrial edge computers.
MSRV: 1.82 | Environment: #![no_std], zero heap allocation
Stack budget: approximately 2.0 KB per OpcUaMonitor instance
(endpoint rule table, session table, rate buckets).
Features
- Security mode enforcement — require
SignAndEncryptfor all channels (global or per-endpoint) - Session/channel tracking — track active sessions with automatic eviction of stale entries
- Replay detection — sequence number validation to detect replayed messages
- Endpoint allowlist — restrict which OPC UA endpoints are reachable (prefix-based matching)
- Message type permissions — per-endpoint control over which operations (Read, Write, Call, Browse) are allowed
- Read-only mode — globally block all Write and Call operations
- Rate limiting — per-channel request rate enforcement via token bucket
Usage
use vs_opcua_monitor::{OpcUaMonitor, EndpointAction, MessagePermissions, OpcUaInspectResult};
use vs_types_ind::OpcUaSecurityMode;
let mut monitor = OpcUaMonitor::new();
monitor.set_min_security_mode(OpcUaSecurityMode::SignAndEncrypt);
// Add an endpoint rule
monitor.add_rule(
b"opc.tcp://plc1",
EndpointAction::Allow,
MessagePermissions::READ_ONLY,
OpcUaSecurityMode::SignAndEncrypt,
100, // max requests/sec
).unwrap();
let result = monitor.inspect(&msg);
if !result.allowed {
// message was blocked
}
License